Cyberpower OLS Rack/Tower 3000VA/2700W
*Stock Are Subject to Availability
SKU
CPOLS3000ERT2UA
Product Reference :
|
$1,829.00
Cyberpower OLS Rack/Tower 3000VA/2700W:
- Online (Double Conversion) UPS Topology
- Generator Compatible
- Zero Transfer Time
- Extended Battery Module Auto-detection
- Critical/Non-critical Load Outlets
- Phone/Fax/Modem/DSL/Network Protection
- Variable Speed Fans
- PowerPanel Management Software
- Rack/Tower Convertible Configurations
- ECO Mode
- Overload Protection
- Smart Battery Management (SBM)
- Surge and Spike Protection
- EMI and RFI Filtration
- Color LCD Panel
- Emergency Power Off (EPO) Port
- SNMP/HTTP Remote Management Capability (Optional)
Specifications:
- Phase: Single Phase
- Form Factor: Rackmount, Tower
- UPS Topology: Online Double Conversion
- Energy Saving Technology: Online ECO Mode Efficiency > 95%
- Generator Compatibility: Yes
- Nominal Input Voltage ( Vac ): 230 ± 10%
- Input Voltage Range ( Vac ): 190 - 300
- Adjustable Voltage Range ( Vac ): 0-30% Load for 80 - 300 Vac | 0-60% Load for 140 - 300 Vac | 0-80% Load for 160 - 300 Vac | 0-100% Load for 190 - 300 Vac
- Input Frequency ( Hz ): 50 ± 10 | 60 ± 10
- Input Frequency Detection: Auto-sensing
- Rated Input Current ( A ): 13
- Input Power Factor: 0.99
- Input Connector Type: IEC C20
- Power Cord Length (m.): 1.5
- Output Capacity (Watts): 2700
- On Battery Waveform: Pure Sine Wave
- On Battery Voltage(s) ( Vac ): 208 ± 1% | 220 ± 1% | 230 ± 1% | 240 ± 1%
- Output Voltage Setting: Configurable
- On Battery Frequency ( Hz ): 50 ± 0.5% | 60 ± 0.5%
- Output Frequency Setting: Configurable
- Power Factor: 0.9
- ECO Mode Voltage Tolerance: ± 15 %
- Overload Protection: Internal Current Limiting, Circuit Breaker, Fuse
- Overload Protection (Line Mode): 110-120% Load for 1 min, >120% Load Immediately
- Overload Protection (Battery Mode): 110-120% Load for 10 sec, >120% Load Immediately
- Overload Protection (Bypass Mode): >130% Load Immediately
- Crest Factor: 3 : 1
- Harmonic Distortion (Linear Load): THD?3%
- Harmonic Distortion (Non-linear Load): THD?5%
- Internal Bypass: Automatic Bypass, Manual Bypass
- Outlet(s) - Total: 9
- Outlet Type: IEC C19 x 1 | IEC C13 x 8
- Outlet(s) - Battery & Surge Protected: 9
- Outlet(s) - Critical Load (CL): 5
- Outlet(s) - Non-Critical Load (NCL): 4
- Typical Transfer Time ( ms ): 0
- Runtime at Half Load ( min ): 13.8
- Runtime at Full Load ( min ): 4.3
- Typical Recharge Time ( Hours ): 4
- Maximum Charging Current ( A ): 1.5
- Start On Battery: Yes
- Smart Battery Management (SBM): Yes
- User-replaceable: Yes - Qualified Personnel Only
- Battery Type: Sealed Lead-acid
- Battery Cartridge: RBP0158
- RBP Quantity ( pcs ): 1
- Battery Quantity (Each RBP) ( pcs ): 6
- Battery Voltage (Each RBP) ( V ): 72
- Compatible Extended Battery Module (EBM): BPSE72V40ART2U
- Extended Battery Module Auto-detection: Yes
- Max. EBM Quantity ( pcs ): 3
- Surge Suppression ( Joules ): 388
- EMI/RFI Filtration: Yes
- Phone/Network Protection RJ11/RJ45 (Combo): 1-in, 1-out
- LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
- LCD Setting & Control: Mode Setting, Alarm Setting, Input & Output, Battery Setting
- HID Compliant USB Port(s): 1
- Dry Contact (with Relay): Yes
- Emergency Power Off (EPO) Port: Yes
- Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
- Management Cable ( pcs ): Power Cord x2, USB Cable x1
- Power Management Software: PowerPanel Business (Recommended)
- SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205
- Enclosure Construction: Metal
- Rackmount Rail: Yes
- Rackmount Ears: Yes
- Dimensions: 438 x 88 x 610mm
- Weight: 26.7kg
- Certifications: CE, RCM